Power-On and Power-Up
5.4 Service Desktop
Manual
138
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
5.4.3
Setting the boot response for the Service Desktop
The NC or MHI desktop settings are used to determine if the NC desktop (Windows desktop)
is displayed after booting the SINUMERIK 840Di sl, or if the HMI user interface, e.g. HMI
Advanced, is started immediately:
●
NC Desktop
Autostart of the HMI application: OFF
●
HMI desktop
Autostart of the HMI application: ON
5.4.4
System information after "Fatal exception error"
After a "fatal exception error" (blue screen), system information is written to the following file:
●
D:\Memory.dmp.
5.4.5
Starting OEM programs
OEM directories
OEM programs can be executed before starting the SINUMERIK system software. These
programs or their respective links must be stored in the following directories:
●
C:\RunOEM\SeqOnce
Programs stored here are started once and sequentially.
●
C:\RunOEM\Seq
Programs stored here are started on every power-up and sequentially.
Note
Sequential: The subsequent program will only be started when the previous program has
been ended.
●
C:\RunOEM\ParOnce
Programs stored here are started once. They run in parallel with the HMI system software.
●
C:\RunOEM\Par
Programs stored here are initiated at every boot. They run in parallel with the HMI system
software.