Power-On and Power-Up
5.1 Preparing for commissioning
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
123
Implementation
1.
Configure the SINUMERIK 840Disl completely on first booting
(Section "First power-up" (Page 124))
2.
Take the PLC default program supplied as the commissioning file for the PLC (basic PLC
program, PLC user program and configuration) or create your own SIMATIC S7 project
and load it into the PLC
(Section "PROFIBUS DP Communication" (Page 229))
3.
Prepare the drives on the PROFIBUS DP for communication:
–
SINAMICS S120 (Section "Drive-commissioning (SINAMICS)" (Page 307))
–
SIMODRIVE 611 universal (Section "Drive-commissioning (SIMODRIVE)" (Page 345))
4.
Perform commissioning of the NC (channels, axes and spindles, etc. (Section "Axes and
5.
Set up the alarm texts (Section "Alarm and message texts" (Page 493))
6.
Perform the commissioning of the drives:
–
SINAMICS S120 (Section "Drive-commissioning (SINAMICS)" (Page 307))
–
SIMODRIVE 611 universal (Section "Drive-commissioning (SIMODRIVE)" (Page 345))
7.
Carry out a dry run for all axes and the spindle.
(Section "840Di sl-specific Data and Functions" (Page 587)
8.
Perform the optimization of the drives:
–
SINAMICS S120: STARTER
–
SIMODRIVE 611 universal: HMI Advanced (Section "Drive optimization with HMI
Advanced" (Page 507)) and/or SimoCom U
9.
Carry out a user data backup (series startup file)
(Section "User data backup/Series commissioning" (Page 541))
10.
Optional: Do a complete data backup (partition and/or hard-disk image):
References:
/IAM2/ Commissioning CNC Part 5, Section "IM8, Backup and restore data"