Function
SINAMICS
G120
G120D
*
0
*
&
&
8
3
&
8
%
&
8
(
&
8
6
&
8
'
&
8
'
(7
SUR
)
&
9
Setting option for two output reactors using parameter p0235 at the SI‐
NAMICS G120C and SINAMICS G120 with PM240-2 FSD … FSF Power
Module
-
✓
✓
✓
✓
✓
-
-
-
10
Efficiency-optimized operation of induction motors
Improved method "Efficiency optimization 2"
✓
✓
✓
✓
✓
✓
✓
✓
✓
11
New setting option for the "Technology application" p0500 = 5 during quick
commissioning
✓
✓
✓
✓
✓
✓
✓
✓
✓
12
Expansion of the available PROFIdrive telegrams in the SINAMICS G120C
to include telegram 350
-
✓
✓
✓
✓
✓
-
-
-
13
An SSI encoder can be parameterized as motor encoder
-
-
-
-
-
✓
-
✓
-
14
Expansion of the "Basic positioner" function to include the feedback signal
from traversing blocks to the higher-level control system
-
-
-
-
-
✓
-
✓
-
15
Expansion to include a feedback signal if a memory card is not inserted in
the inverter:
● Parameter r9401 as BiCo parameter for the optional feedback signal to
the higher-level control system.
● New alarm A01101
✓
✓
✓
✓
✓
✓
✓
✓
✓
16
Expansion of the "End stop control" function on the following inverters:
● SINAMICS G120
● SINAMICS G120C
● SINAMICS G120D
✓
✓
✓
✓
✓
✓
✓
✓
-
17
Expansion of the technology controller to include the following functions:
● Gain K
P
and integral time T
N
can be adapted.
● The system deviation can be used as adaptation signal
-
-
✓
-
✓
-
-
-
-
18
Expansion to the torque limiting for SINAMICS G120 inverters with
CU230P‑2 Control Unit
✓
✓
✓
✓
✓
✓
✓
✓
✓
Changes in the current manual (Page 5)
Appendix
A.1 New and extended functions
SINAMICS G120C converter
430