4. Select the settings as shown in the diagram and start the data backup.
5. Wait until STARTER signals that the data backup has been completed.
6. Close the screen forms.
7. Go offline.
8. Switch off the inverter power supply.
9. Wait until all LEDs on the inverter are dark.
10.Switch on the inverter power supply again.
Your settings become effective after switching on.
You have now transferred your settings from a memory card to the inverter.
Procedure with Startdrive
Proceed as follows to transfer settings from a memory card to the inverter:
1. Go online.
2. Select "Online & diagnostics".
Saving settings and series commissioning
7.1 Saving settings on a memory card
SINAMICS G120C converter
328
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34263257B AF