A.1.2
Firmware version 4.7 SP6
Table A-2
New functions and function changes in firmware 4.7 SP6
Function
SINAMICS
G120
G120D
*
0
*
&
&
8
3
&
8
%
&
8
(
&
8
6
&
8
'
&
8
'
(7
SUR
)
&
1
Support for the Power Module PM240-2, FSF frame sizes
-
-
✓
✓
✓
✓
-
-
-
Support of PM240P‑2 Power Modules frame sizes FSD … FSF
-
-
✓
✓
✓
-
-
-
-
Support of safety function Safe Torque Off (STO)via the terminals of the
PM240‑2 Power Module, frame size FSF and PM240P‑2 Power Module
FSD … FSF
You can find additional information in the "Safety Integrated" function man‐
ual.
Overview of the manuals (Page 459)
-
-
-
-
✓
✓
-
-
-
2
Support for Power Module PM330 JX frame size
-
-
✓
-
-
-
-
-
-
3
Support for 1PC1 induction motors
✓
✓
✓
✓
✓
✓
✓
✓
✓
4
The control of synchronous reluctance takes into account the inductance
of the output reactor.
-
-
✓
-
-
-
-
-
-
5
Support of motor temperature sensor Pt1000
✓
✓
✓
✓
✓
✓
✓
✓
✓
6
New p4621 parameter for disabling PTC short-circuit monitoring
-
-
-
-
-
-
✓
✓
✓
7
Revision of the thermal motor model for protecting the motor against dam‐
age due to overheating in the stator or rotor
✓
✓
✓
✓
✓
✓
✓
✓
✓
8
Changing the quick commissioning in the "Standard Drive Control" appli‐
cation class:
The motor data identification is no longer permanently set to p1900 = 12;
instead, users select the appropriate motor data identification.
Factory setting: p1900 = 2.
-
✓
✓
✓
✓
✓
-
-
-
9
The free function blocks are also available in the SINAMICS G120C.
✓
✓
✓
✓
✓
✓
✓
-
-
Changes in the current manual (Page 5)
Appendix
A.1 New and extended functions
SINAMICS G120C converter
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34263257B AF
431