![Siemens SINAMICS G120C Operating Instructions Manual Download Page 64](http://html.mh-extra.com/html/siemens/sinamics-g120c/sinamics-g120c_operating-instructions-manual_376473064.webp)
Do not cover the ventilation openings of the braking resistor.
Dimensions and drilling patterns
+¸KH
%UHLWH
7LHIH
+
%
Figure 4-18 Dimensions of the braking resistor
Table 4-5
Dimensions [mm]
Article number
Total dimensions
Drilling dimensions
Width
Height
Depth
W
H
Fixing
6SL3201-0BE14-3AA0
105
295
100
72
266
M4 / 3 Nm
6SL3201-0BE21-0AA0
105
345
100
72
316
M4 / 3 Nm
6SL3201-0BE21-8AA0
175
345
100
142
316
M4 / 3 Nm
6SL3201-0BE23-8AA0
250
490
140
217
460
M5 / 6 Nm
JJY:023422620001
220
470
180
187
430
M5 / 6 Nm
JJY:023424020001
220
610
180
187
570
M5 / 6 Nm
JJY:023434020001
350
630
180
317
570
M5 / 6 Nm
JJY:023454020001
1)
JJY:023422620001 ∥
JJY:023434020001
220
350
470
630
180
180
187
317
430
570
M5 / 6 Nm
M5 / 6 Nm
JJY:023464020001
1)
JJY:023434020001 ∥
JJY:023434020001
350
350
630
630
180
180
317
317
570
570
M5 / 6 Nm
M5 / 6 Nm
Mount the braking resistor using screws, nuts and washers.
1)
The article number contains two braking resistors, which must be switched in parallel
Assignment of braking resistor to inverter:
Installing
4.7 Mounting the braking resistor
SINAMICS G120C converter
64
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34263257B AF