Configuration
3.4 Configuration Save & Restore
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
122
Configuration Manual, 06/2016, C79000-G8976-C252-11
3.4
Configuration Save & Restore
This section describes commands for displaying, saving and restoring configuration settings.
3.4.1
write startup-config
Description
With this command, you save the changes to the configuration in the configuration file.
The use of this command is required in the Trial mode. It can also be used in "auto save
mode".
Requirement
●
The Trial mode is activated.
●
You are in the Privileged EXEC mode.
The command prompt is:
*cli(...)#
Syntax
Call the command without parameter assignment:
write startup-config
Result
The changes are saved in the configuration file.
Use the
restart
command without parameters to restart the system with this configuration.
Further notes
You enable the auto save function or disable the Trial mode with the
auto-save
command.
You disable the auto save function or enable the Trial mode with the
no auto-save
command.