![Siemens SCALANCE XM-400 Configuration Manual Download Page 880](http://html.mh-extra.com/html/siemens/scalance-xm-400/scalance-xm-400_configuration-manual_382069880.webp)
Security and authentication
11.7 Port-based Network Access Control (Dot1X)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
880
Configuration Manual, 06/2016, C79000-G8976-C252-11
Syntax
Call up the command with the following parameters:
set dot1x mac-auth mac-addr count <num-of-addresses (1-100)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
num-of-addresses
Maximum number of devices
1 ... 100
Result
The maximum number of devices for the port has been specified.
Further notes
You display this setting and other information with the
show dot1x
command.
11.7.3.15
dot1x reauthentication
Description
With this command, you enable the 802.1x Re-Authentication function for the selected
interface. When the function is enabled, the authenticator repeats authentication of the client
periodically,
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
dot1x reauthentication
Result
Periodic authentication is enabled for the selected interface.
Summary of Contents for SCALANCE XM-400
Page 882: ......