System time
5.3 SNTP Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
170
Configuration Manual, 06/2016, C79000-G8976-C252-11
Parameter
Description
hh
Number of hours difference
mm
Number of minutes difference
Enter the time difference as follows:
●
with sign
●
without spaces
●
Hours and minutes both two digits (with leading zero)
Default: no time difference
Result
The time zone of the system time is configured.
Further notes
You can display the settings of this function and other information with the
show sntp
status
command.
5.3.3.3
sntp unicast-server
Description
With this command, you configure an SNTP unicast server.
Requirement
●
The addressing mode of the SNTP client is configured as "unicast".
●
You are in the SNTP Configuration mode.
The command prompt is:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
sntp unicast-server {ipv4 <ucast_addr> | fqdn-name <FQDN> | ipv6 <ip6_addr>}
[port<1025-36564>][poll<seconds(16-16284)>] [secondary]
The parameters have the following meaning:
Parameter
Description
Range of values / note
ipv4
Keyword for an IP address
-
ucast_addr
Value for an IPv4 unicast address
Enter a valid IPv4 unicast ad-
dress.
fqdn-name
Keyword for a domain name
-
Summary of Contents for SCALANCE XM-400
Page 882: ......