Layer 2 management protocols
8.5 Ring redundancy and standby connection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
471
Syntax
Call the command without parameters:
clear hrp counters
Result
The HRP counters have been reset.
8.5.2
clear ring-redundancy manager counters
Description
With this command, you reset the following counters:
●
How often the device as redundancy manager switched to the active status, i.e. closed
the ring.
●
The maximum delay time of the test frames of the redundancy manager.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
or
cli#
Syntax
Call the command without parameters:
clear ring-redundancy manager counters
Result
The counters are reset.
8.5.3
clear standby counter
Description
With this command, you reset the counters of the standby function.
Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#