Network protocols
7.8 SNMP
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
408
Configuration Manual, 06/2016, C79000-G8976-C252-11
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
snmp v1-v2 readonly
Result
Write access for SNMPv1 and SNMPv2 PDUs is blocked.
Further notes
You release write access for SNMPv1 and SNMPv2 PDUs with the
no snmp v1-v2 readonly
command.
7.8.2.19
no snmp v1-v2 readonly
Description
With this command, you enable write access for SNMPv1 and SNMPv2 PDUs.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no snmp v1-v2 readonly
Result
Write access for SNMPv1 and SNMPv2 PDUs is enabled.
Further notes
You block write access for SNMPv1 and SNMPv2 PDUs with the
snmp v1-v2 readonly
command.
Summary of Contents for SCALANCE XM-400
Page 882: ......