Load control
10.1 Rate control
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
777
The parameters have the following meaning:
Parameter
Description
Range of values / note
rate-value
Value for the in data rate in Kbps
Default:
The data rate is set to 0. The
outgoing data stream is not lim-
ited.
If you do not select any parameters from the parameter list, the default value is used.
Result
The limitation of the outgoing data stream of the interface with the data rate is enabled.
Further notes
You disable the function with the
no rate-limit output
command.
10.1.2.2
no rate-limit output
Description
With this command, you disable the data rate for limiting the outgoing data stream of the
interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no rate-limit output
Result
The limitation of the outgoing data stream of the interface with the data rate is disabled.
Further notes
You enable the function with the
rate-limit output
command.