Diagnostics
12.1 Event and fault handling
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
899
Result
The setting deciding which messages of the device are not stored or forwarded is
configured.
Further notes
You display the status of the events and the clients with the
show events config
command.
You configure which of the various message types of the device will be stored or forwarded
with the
event config
command.
12.1.6.6
severity
Description
With this command, you configure the threshold values for the sending of system event
notifications.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
severity { mail | log | syslog } { info | warning | critical }
The parameters have the following meaning:
Parameter
Description
Range of values / note
Specifies the threshold value for send-
ing system event messages by e-mail.
-
log
Specifies the threshold value for enter-
ing system event messages in the log
table.
-
syslog
Specifies the threshold value for enter-
ing system event messages in the
Syslog file.
-
info
System events are processed as of the
severity level "
Information
".
-
warning
System events are processed as of the
severity level "
Warning
".
-
critical
System events are processed as of the
severity level "
Critical
".
-
Summary of Contents for SCALANCE XM-400