Layer 2 management protocols
8.6 Unicast
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
486
Configuration Manual, 06/2016, C79000-G8976-C252-11
8.6
Unicast
The commands in this section configure the procedures for handling Unicast frames.
The commands allow the following:
●
Filtering of Unicast frames
●
Blocking of ports
●
Automatic learning of Unicast
●
Blocking unknown Unicast frames.
With the "show" commands, you can display the configuration data.
8.6.1
The "show" commands
This section describes commands with which you display various settings.
8.6.1.1
show unicast-block config
Description
This command shows the unicast blocking settings for ports.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
or
cli#
Syntax
Call up the command with the following parameters:
show unicast-block config [port <interface-type> <interface-id)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
port
Keyword for a port description
-
interface-type
Type or speed of the interface
Enter a valid interface
interface-id
Module no. and port no. of the interface
For information on names of interfaces and addresses, refer to the section "Interface
identifiers and addresses (Page 42)".
Summary of Contents for SCALANCE XM-400