Page EN-6
XPS/XCT Series Transducers – OPERATION MANUAL
7ML19985QM82
Englis
h
Outline and Dimensions
Mounting
•
Mount the transducer so that it is above the maximum material level by at least the
blanking value. Refer to the associated controller manual.
•
On liquid applications, mount the transducer face parallel to the liquid surface. On solids
applications, use a Siemens Milltronics Easy Aimer to help aim the transducer.
•
Do not overtighten. Most applications require only hand tightening of the mounting
hardware. Connect a safety chain from the transducer to a structural member to secure
installation. Consider using the optional temperature sensor when a flanged transducer
is used, when a fast temperature response is required, or in high temperature vessels.
Dimension
XPS-10
XPS-15
XPS-30
XPS-40
XCT-8
XCT-12
A
88 mm (3.4") 121 mm (4.8") 175 mm (6.9") 206 mm (8.1") 88 mm (3.4") 121 mm (4.8")
B
122 mm (4.8") 132 mm (5.2") 198 mm (7.8") 229 mm (9.0") 122 mm (4.8") 132 mm (5.2")
C
to suit ANSI, DIN and JIS standards
D*
128 mm (5.0") 138 mm (5.4") 204 mm (8.0") 235 mm (9.2") 128 mm (5.0") 138 mm (5.4")
E
124 mm (4.9") 158 mm (6.2") n / a
n / a
n / a
n / a
F
152 mm (6.0") 198 mm (7.8") n / a
n / a
n / a
n / a
G
28 mm (1.1")
28 mm (1.1")
28 mm (1.1")
28 mm (1.1")
28 mm (1.1")
28 mm (1.1")
* nominal
WARNING:
Optional Split Flange, Bonded Flange, and Easy Aimer configurations
are not suitable for pressure applications.
WARNING: Special handling precautions must be taken to protect the
face of the transducer from any damage.
Note:
For pressure tight applications, install transducers hand tight plus ½ turn to 1½
turns. PTFE tape or other appropriate sealant may be used to aid in sealing the threads for
use in pressure applications.
B
A
C
B
F
E
C
D
G
standard
radiating
face
optional bonded flange
refer to associated instructions
optional split flange
refer to associated instructions
optional
submergence shield
refer to associated
instructions
Summary of Contents for MAG 1100
Page 1: ... MFDUSPNBHOFUJD GMPXNFUFST 1 8 0QFSBUJOH OTUSVDUJPOT p 4 53 4 ...
Page 47: ......
Page 76: ... MFDUSPNBHOFUJD GMPXNFUFST 1 8 0QFSBUJOH OTUSVDUJPOT p 4 53 4 ...
Page 140: ...65 SITRANS F M 8 Commissioning 8 3 2 MAG 5000 CT and MAG 6000 CT Menu overview ...
Page 164: ...Tab 36 Siemens MultiRanger 100 ...
Page 165: ...Instruction Manual April 2006 100 200 multiranger ...
Page 396: ...Page 222 MultiRanger 100 200 INSTRUCTION MANUAL 7ML19981FB05 mmmmm Parameters ...
Page 445: ...Operation Manual February 2005 ECHOMAX xrs 5 ...
Page 446: ...IQ300IX fm Page 5 Tuesday October 2 2001 1 43 PM ...
Page 454: ...Page EN 8 XRS 5 Series Transducers OPERATION MANUAL 7ML19985QT81 mmmmm English ...
Page 462: ...Side DA 8 XRS 5 Serie Transducere DRIFTSVEJLEDNING 7ML19985QT81 mmmmm Dansk ...
Page 470: ...Seite 8 Ultraschallsensoren XRS 5 BETRIEBSANLEITUNG 7ML19981QT81 mmmmm Deutsch ...
Page 478: ...Σελίδα EL 8 Μορφοτροπείς σειράς XRS 5 ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ 7ML19985QT81 mmmmm Ελληνικά ...
Page 486: ...Página ES 8 Sensores XRS 5 MANUAL DE OPERACIÓN 7ML19985QT81 mmmmm Español ...
Page 494: ...Page FR 8 Transducteurs Série XRS 5 MANUEL D UTILISATION 7ML19985QT81 mmmmm Français ...
Page 502: ...Pagina IT 8 Trasduttori serie XRS 5 MANUALE OPERATIVO 7ML19985QT81 mmmmm Italiano ...
Page 510: ...Pagina NE 8 XRS 5 serie transducers BEDIENINGSHANDLEIDING 7ML19985QT81 mmmmm Nederlands ...
Page 518: ...Página PT 8 Transdutores Série XRS 5 MANUAL DE FUNCIONAMENTO 7ML19985QT81 mmmmm Português ...
Page 526: ...sivu SU 8 XRS 5 sarjan anturit KÄYTTÖOPAS 7ML19985QT81 mmmmm Suomi ...
Page 534: ...Sida SV 8 XRS 5 Transducerserier ANVÄNDARMANUAL 7ML19985QT81 mmmmm Svenska ...
Page 539: ...Operation Manual February 2005 ECHOMAX xps xct ...
Page 540: ...IQ300IX fm Page 5 Tuesday October 2 2001 1 43 PM ...
Page 550: ...Page EN 10 XPS XCT Series Transducers OPERATION MANUAL 7ML19985QM82 English ...
Page 555: ...Tab 37 Siemens XRS 5 Ultrasonic Level Sensors ...
Page 556: ...Operation Manual February 2005 ECHOMAX xrs 5 ...
Page 557: ...IQ300IX fm Page 5 Tuesday October 2 2001 1 43 PM ...
Page 565: ...Page EN 8 XRS 5 Series Transducers OPERATION MANUAL 7ML19985QT81 mmmmm English ...
Page 573: ...Side DA 8 XRS 5 Serie Transducere DRIFTSVEJLEDNING 7ML19985QT81 mmmmm Dansk ...
Page 581: ...Seite 8 Ultraschallsensoren XRS 5 BETRIEBSANLEITUNG 7ML19981QT81 mmmmm Deutsch ...
Page 589: ...Σελίδα EL 8 Μορφοτροπείς σειράς XRS 5 ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ 7ML19985QT81 mmmmm Ελληνικά ...
Page 597: ...Página ES 8 Sensores XRS 5 MANUAL DE OPERACIÓN 7ML19985QT81 mmmmm Español ...
Page 605: ...Page FR 8 Transducteurs Série XRS 5 MANUEL D UTILISATION 7ML19985QT81 mmmmm Français ...
Page 613: ...Pagina IT 8 Trasduttori serie XRS 5 MANUALE OPERATIVO 7ML19985QT81 mmmmm Italiano ...
Page 621: ...Pagina NE 8 XRS 5 serie transducers BEDIENINGSHANDLEIDING 7ML19985QT81 mmmmm Nederlands ...
Page 629: ...Página PT 8 Transdutores Série XRS 5 MANUAL DE FUNCIONAMENTO 7ML19985QT81 mmmmm Português ...
Page 637: ...sivu SU 8 XRS 5 sarjan anturit KÄYTTÖOPAS 7ML19985QT81 mmmmm Suomi ...
Page 645: ...Sida SV 8 XRS 5 Transducerserier ANVÄNDARMANUAL 7ML19985QT81 mmmmm Svenska ...
Page 650: ...Tab 38 Siemens XPS XCT Transducers ...
Page 651: ...Operation Manual February 2005 ECHOMAX xps xct ...
Page 652: ...IQ300IX fm Page 5 Tuesday October 2 2001 1 43 PM ...
Page 662: ...Page EN 10 XPS XCT Series Transducers OPERATION MANUAL 7ML19985QM82 English ...