5.8.5.3.4
Save permanent
If the
parameter is activated, the taught-in match code are kept even after
the LECTOR
®
620 is switched off.
As the information is stored in the device's internal memory, on the Micro-SD memory card
and/or parameter memory module CMC600, the save operation may be delayed.
5.8.6
Filters/Sorters for the output formatting
You can use the graphical interface on the
Filters/Sorters for the output formatting
tab to
restrict (filter) data for outputting the reading results and define the sequence in which the
data is output (sorted). By combining filters and sorters, you can therefore individually influ-
ence data output.
Any number of filters and sorters can be graphically arranged for this between the device
and PC. The filters can also be arranged in parallel.
You can add further filters and sorters by pulling down the corresponding symbols. The fil-
ters or sorters can be copied by dragging the symbols while holding down the Ctrl pushbut-
ton. To delete a symbol, drag it over to the recycle bin. Selected symbols can also be
removed by pressing the E
NTF
. button.
During filtering, you can use the button to define the variable and condition for filtering.
Example: (CL) C
ODELÄNGE
= 10: Only codes with a code length of exactly 10 characters are
output.
During sorting, you can use the button to select the variable used to sort the reading re-
sults. The option is also available to sort the results in ascending or descending order.
Example: (CL) C
ODELÄNGE
- A
UFSTEIGEND
: The codes with the shortest code length are output
first.
5.8.6.1
Filters/Sorters for Output Format1
You can use the graphical interface of the
Filters/Sorters for Output Format1
group to re-
strict (filter) data for output of the reading results and define the sequence in which the data
is output (sort). By combining filters and sorters, you can therefore individually influence
data output.
Any number of filters and sorters can be graphically arranged for this between the device
and PC. The filters can also be arranged in parallel.
You can add further filters and sorters by pulling down the corresponding symbols. If you
move the symbols while holding down the Ctrl key, you can copy filters or sorters. You can
delete the symbols by moving them to the trash. Selected symbols can also be removed by
pressing the D
EL
. key.
During filtering, you can use the button to define the variable and condition for filtering.