1
Notes on this document
This document contains the
online help
of device description LECTOR620.sdd (for operati-
on and configuration with SOPAS Single Device or SOPAS-ET).
Used symbols
To gain easier access, some information in this documentation is emphasized as follows:
Intended use
The camera-based LECTOR
®
620 is an intelligent sensor for the automatic, stationary deco-
ding of codes on moving or still-standing objects. It reads all common 1D codes (barcodes)/
2D codes (stacked codes/matrix codes). Via its host interface, the LECTOR
®
620 transmits
the reading data to a higher-level computer for further processing.
Safety information
Read the LECTOR
®
620 operating instructions and familiarize yourself with the device
and its functions.
To avoid the dazzle caused by integrated illumination, do not look into the reading win-
dow when switching the LECTOR
®
620 on and off.
Hint
This symbol points out specific features.
Note
This symbol indicates additional settings in the SOPAS-ET configuration software.
Important
This symbol indicates supplementary technical documentation.
The accessible radiation of the laser LEDs poses no risk.
Temporary, irritating, optical effects on the human eye (e.g. dazzle, blindness from flash,
after-images, impairment of color vision) cannot be completely ruled out, particularly with
low ambient brightness. Precautionary measures are not required. Caution - incorrect use
may result in the user being exposed to hazardous radiation.
Do not intentionally look directly into the light sources for long periods of times.
Observe the currently applicable regulations on photobiological safety of lamps and
lamp systems as well as laser protection.
Hint
No maintenance is required in order to ensure compliance with risk group RG 1/laser pro-
tection class 1.