Chapter
5
ONLINE HELP SOPAS
LECTOR®620
112
©
SICK AG · Germany · All rights reserved · Subject to change without notice
8013778/Y269/2013-11-27
Parameters
5.8.9.1.1
Resetting counter statuses
Pressing the
button resets all counters.
To reset the permanent flash memory in addition to this, the
Saving current counter status-
button must also be pressed.
5.8.9.1.2
Saving current counter statuses
Pressing the
Saving current counter statuses
button saves all values to the device's flash
memory. This means the values are available without a permanent supply voltage, i.e., the
values are still saved after restarting the device.
5.8.9.1.3
Application counter
Various events can be selected as application counters.
Counter
Description
Deactivated
No event counting
Input 1
Number of input 1 activations
Input 2
Number of input 2 activations
Ext. input 1
Number of external input 1 activations
Ext input 2
Number of external input 2 activations
Output 1
Number of output 1 activations
Output 2
Number of output 2 activations
Output 3
Number of output 3 activations
Output 4
Number of output 4 activations
Ext. output 1
Number of external output 1 activations
Ext. output 2
Number of external output 2 activations
Condition match 1
Number of codes read that correspond to the match code
from
B
EDINGUNG
M
ATCH
1
Condition MultCodes1
Number of codes read that correspond to the number speci-
fied in
B
EDINGUNG
M
ULT
C
ODES
1
Condition TeachIn1
Number of codes read that correspond to the match code
from
B
EDINGUNG
T
EACH
I
N
1
Condition TeachIn2
Number of codes read that correspond to the match code
from
B
EDINGUNG
T
EACH
I
N
2
(NZ) Number of mismatches
Number of codes read that do not fulfill the match conditi-
ons
(NY) Number of no matches
Number of objects without a match
(GNC) Global number of codes
Number of codes read
(NRVB) Global number of valid
released codes
Number of valid released codes
(NC) A
NZ
. L
ESETORE
Number of reading gates
(SCGR) Superordinate counter: Good
Read
Superordinate Good Read counter; remains in case of a new
parameterization (reset via power cycle)
(SCNR) Superordinate counter: No
Read
Superordinate No Read counter; remains in case of a new
parameterization (reset via power cycle)
(RR) Read rate
Ratio between Good Reads (SCGR) and number of reading
gates