ONLINE HELP SOPAS
Chapter
5
LECTOR®620
Parameters
8013778/Y269/2013-11-27
©
SICK AG · Germany · All rights reserved · Subject to change without notice
33
5.4.1.4.3
Green feedback spot
The
parameter is used to select the condition causing a green LED
spot to be illuminated in the reading area. As a result, an optical notification can be set up
for a specific event.
The timeframe for illumination is defined using the
• O
FF
: The LED spot never illuminates.
• G
OOD
R
EAD
: The green LED spot illuminates if reading was successful.
• N
O
R
EAD
: The green LED spot illuminates if reading was unsuccessful.
• T
EACH
-
IN
1 OK: The green LED spot illuminates if the M
ATCHCODE
T
EACH
-
IN
1 was read in suc-
cessfully.
• T
EACH
-
IN
1 NOK: The green LED spot illuminates if the M
ATCHCODE
T
EACH
-
IN
1 was not read
in successfully.
• T
EACH
-
IN
2 OK: The green LED spot illuminates if the M
ATCHCODE
T
EACH
-
IN
2 was read in suc-
cessfully.
• T
EACH
-
IN
2 NOK: The green LED spot illuminates if the M
ATCHCODE
T
EACH
-
IN
2 was not read
in successfully.
• C
ONDITION
M
ATCH
1: The green LED spot illuminates if the read code corresponds to the
matchcode of C
ONDITION
M
ATCH
1.
• C
ONDITION
M
ULT
C
ODES
1: The green LED spot illuminates if the number of read codes cor-
responds to the required number from C
ONDITION
M
ULT
C
ODES
1.
• C
ONDITION
T
EACH
I
N
1: The green LED spot illuminates if the read code corresponds to the
matchcode from C
ONDITION
T
EACH
I
N
1.
• C
ONDITION
T
EACH
I
N
2: The green LED spot illuminates if the read code corresponds to the
matchcode from C
ONDITION
T
EACH
I
N
2.
5.4.1.4.4
Duration
The
parameter is used to define the timeframe for the optical notification (
5.4.1.5
Image filters
Parameters for optimizing the camera image in the case of noise or special code markings
are combined in the
group.
5.4.1.5.1
Noise suppression
Image smoothing is switched on and off via the
parameter to pick out
the code clearly against the background.