5.8.3.1.4
Data output mode
The
parameter is used to define the frequency of data output.
• S
INGLE
: The reading results are output once.
• M
ULTIPLE
: The reading results are initially output once. After a certain period of time (
), the data is output again. With a suitable setting, you can dif-
ferentiate between different objects with identical codes.
Label timeout
If the A
S
SOON
AS
POSSIBLE
value is selected for the
parameter, you can use the
parameter to define the duration up to renewed output of the data. During
this period, the data is output again as long as the code is in the reading area.
The unit can be selected in the
Condition timeout
If the A
S
SOON
AS
POSSIBLE
value is selected for the
parameter, you can use the
parameter to define the duration up to renewed output of the data. Du-
ring this period, the data is output again as long as the condition for data output (
The unit can be selected in the
5.8.3.1.5
Label timeout
5.8.3.1.6
Condition timeout
5.8.3.1.7
Delay
If the E
ND
OF
TRIGGER
value is selected for the
parameter, the
parameter
can be used to hold back the data for a certain period after the reading gate has been
closed. This allows the timings to be adapted to the control (PLC).
The unit can be selected via the
parameter.
A long delay time slows down the image output. The image output can speed up if the
delay values are low.
5.8.3.1.8
Output delay
parameter is used to choose between configuration with units of length or
configuration with units of time for the
,
, and
parameters
• T
RACK
CONTROLLED
: The entries for the parameters are made in mm.
• T
IME
CONTROLLED
: The entries for the parameters are made in ms.