
ONLINE HELP SOPAS
Chapter
5
LECTOR®620
Parameters
8013778/Y269/2013-11-27
©
SICK AG · Germany · All rights reserved · Subject to change without notice
95
APC09 - Application counter 9
Definable counter 9
APC10 - Application counter 10
Definable counter 10
TS - Time stamp
Time stamp of reading gate (start reading gate)
RR - Read rate
Ration between Good Reads (SCGR) and num-
ber of reading gates
OGA - Distance between two objects
Object to previous object in mm
Match counter…
Description
Match1
Counter how often condition Match1 was ful-
filled (object related)
TeachIn1
Counter how often condition TeachIn1 was ful-
filled (object related)
TeachIn2
Counter how often condition TeachIn2 was ful-
filled (object related)
Superordinate counter….
Description
Match1
Counter how often condition Match1 was ful-
filled
TeachIn1
Counter how often condition TeachIn1 was ful-
filled
TeachIn2
Counter how often condition TeachIn2 was ful-
filled
Special character…
Description
NUL 00H
Null
SOH 01H
Start of heading
STX 02H
Start of text
ETX 03H
End of text
EOT 04H
End of transmission
ENQ 05H
Enquiry
ACK 06H
Acknowledge
BEL 07H
Bell
BS 08H
Backspace
HT 09H
Horizontal tab
LF 0AH
NL line feed, new line
VT 0BH
Verticval tab
FF 0CH
NP from feed, new page
CR 0DH
Carriage return
SO 0EH
Shift out
SI 0FH
Shift in
DLE 10H
Data link escape
DC1 11H
Device control 1
DC2 12H
Device control 2
DC3 13H
Device control 3
DC4 14H
Device control 4
NAK 15H
Negative acknowledge
More obj. related items…
Description