Chapter
5
ONLINE HELP SOPAS
LECTOR®620
46
©
SICK AG · Germany · All rights reserved · Subject to change without notice
8013778/Y269/2013-11-27
Parameters
5.7.2.5
2/5 Interleaved
parameter is activated, decoding is activated for the code type.
As only activated code types are processed, you can increase the processing speed by
specifically activating/deactivating the required code types.
• Code name:
or ITF (2-value)
• Character set: Numeric characters
• Structure: 5 code elements per character, 2 of which wide and 3 narrow (characters at
uneven positions are represented by bars. Characters at even positions are represented by
gaps.)
• Intrinsic reliability: Low
• Space required: Low (with up to 18 characters)
• Standard: ISO/IEC 16390
• Area of application: Packet and postal service
5.7.2.6
Code 93
parameter is activated, decoding is activated for the code type.
As only activated code types are processed, you can increase the processing speed by
specifically activating/deactivating the required code types.
• Code name:
(4-value)
• Character set: 43 alphanumeric characters (10 digits, 26 upper-case letters, 7 special
characters: Blanks, -, ., $, /, + and %)
• Intrinsic reliability: Medium
• Space required: Low
• Standard: ISO/IEC 16388
• Area of application: Packet and postal service
5.7.2.7
Code 128 Family
parameter is activated, decoding is activated jointly for code types
and
must be deactivated.)
As only activated code types are processed, you can increase the processing speed by
specifically activating/deactivating the required code types.