Chapter
5
ONLINE HELP SOPAS
LECTOR®620
70
©
SICK AG · Germany · All rights reserved · Subject to change without notice
8013778/Y269/2013-11-27
Parameters
5.7.14.2.5
Fixed length 4
A fixed symbol size can be selected using the
parameter. Only codes with this
symbol size are read.
Defining specific permissible symbol sizes restricts the spectrum of codes to be read. This
can lead to a reduction in the decoding time.
5.7.14.2.6
Fixed length 5
A fixed symbol size can be selected using the
parameter. Only codes with
this symbol size are read.
Defining specific permissible symbol sizes restricts the spectrum of codes to be read. This
can lead to a reduction in the decoding time.
5.7.14.2.7
Allow rectangular data fields
If the
REE
, square (e.g. 16 x 16) and rectangular (e.g. 8
x 18) symbols are identified if the
parameter is activated.
5.7.14.3
Reducing evaluation time
The decoding time is adapted to the application on site and optimized via the parameters
for the
5.7.14.3.1
Code surrounded by patterns
parameter is activated, patterns/lines (e.g. strip conduc-
tors on printed circuit board) in the code environment are ignored during evaluation.
As a result, the reading concentrates on the code elements and the decoding time is redu-
ced.
Codes with poor quality are generally ignored if the function is activated.
5.7.14.3.2
Code surrounded by text
parameter is activated, text (e.g. on packaging) in the code
environment are ignored during evaluation.