28 INT-GSM
SATEL
Value
– value to be set (if the type of data provides for sending a sequence of
characters, you can enter up to 13 characters).
Exit delay clearing
(no additional parameters to configure).
Quick arm
– select the arming mode which is to be activated.
The partitions must be controlled by user code.
The zones must not have the “Bypass disabled” option enabled.
The outputs must be the 24. MONO
S
WITCH
, 25. BI
S
WITCH
, 105. S
HUTTER UP
,
106. S
HUTTER DOWN
or R
EMOTE SWITCH
type.
The INTEGRA CONTROL application can control the KNX system, if the INT-KNX or
INT-KNX-2 module is connected to the control panel.
5.5.3 Defining the macro commands
1. Click the “Read” button to read the macro command related data from the module.
2. Click the “Definitions” tab.
3. Click the “New macro” button. A new macro command will appear in the list.