Satel INT-GSM Manual Download Page 1

 

 

 

 
 
 
 
 

INT-GSM 

 

GPRS communication module 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

 

Firmware version 1.00 

int-gsm_en 07/18 

SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gda

ń

sk • POLAND 

tel. +48 58 320 94 00 

www.satel.eu 

Summary of Contents for INT-GSM

Page 1: ...INT GSM GPRS communication module Firmware version 1 00 int gsm_en 07 18 SATEL sp z o o ul Budowlanych 66 80 298 Gdańsk POLAND tel 48 58 320 94 00 www satel eu ...

Page 2: ...d on the enclosure base FreeRTOS is used in this device www freertos org SATEL s goal is to continually upgrade the quality of its products which may result in some changes of their technical specifications and firmware The current information on the introduced modifications is available on our website Please visit us http www satel eu Hereby SATEL sp z o o declares that this device is in complian...

Page 3: ...trol 17 5 2 5 Reporting 19 5 2 6 Remote firmware update 20 5 3 User functions definition 22 5 4 Virtual keypad 22 5 5 Macro commands 23 5 5 1 Groups 24 5 5 2 Definitions 25 5 5 3 Defining the macro commands 28 6 Remote programming operating of control panel via module 33 6 1 GUARDX program 33 6 1 1 Configuring the GUARDX program settings 33 6 1 2 Initiating connection by SMS message 35 6 1 3 Initi...

Page 4: ...module is to log in Advanced 192 bit key based algorithm for encryption of GPRS transmissions Reporting Reporting events to two monitoring stations via GSM network Two transmission paths GPRS SMS messages Defining priority for transmission paths Messaging Event notifications in the form of automatically created SMS messages based on descriptions from the control panel event log 16 telephone number...

Page 5: ...ted to the RS 232 port of the control panel Updating the firmware via GPRS communication and the UPSERV update server remote update Interaction with the ETHM 1 Plus Ethernet module GPRS used as backup communication path for Ethernet network Defining priority for different paths of event reporting Ethernet GPRS and SMS Dual Path Reporting compliant with EN 50136 Electronics board RS 485 port to ena...

Page 6: ...4 INT GSM SATEL Fig 1 Module connected to the INTEGRA INTEGRA Plus alarm control panel Fig 2 Module connected to the ETHM 1 Plus Ethernet module ...

Page 7: ... card PIN code in the module is not recommended if the card requires entering the PIN code SIM1 LED The LED is on when the card installed in the SIM 1 slot is active SIM2 LED The LED is on when the card installed in the SIM 2 slot is active BUS LED Flashing when data exchange with the control panel is in progress LOG LED ON power OK flashing communication via the module in progress RS 232 port pin...

Page 8: ... be installed shall meet the requirements for fireproof enclosures If the module is to be directly connected to the alarm control panel it should be installed in the same enclosure with the control panel This will facilitate connecting the RS 232 ports of control panel and module 1 Secure the module electronics board in the enclosure 2 If the module is to supervise the enclosure tamper switch conn...

Page 9: ...It is recommended that unshielded non twisted cable to be used 4 4 1 Connecting to the alarm control panel Fig 4 The way of connecting the module with the alarm control panel 1 Connect the 12V COM DTM and CKM module terminals to the control panel terminals Fig 4 To connect the 12V and COM terminals use flexible conductors with a cross section of 0 5 0 75 mm2 or rigid conductors with a cross sectio...

Page 10: ...ol panel with RJ type connector socket Fig 6 Wiring diagram of the cable connecting RS 232 ports of INT GSM module and INTEGRA control panel with PIN5 connector socket 4 4 2 Connecting to the ETHM 1 Plus module 4 2 Connecting to the ETHM 1 Plus module Fig 7 The way of connecting the INT GSM module to the ETHM 1 Plus module ...

Page 11: ...ig 8 3 Power up the alarm system Logging the telephone into the GSM network may take a few minutes If the module is to send data in GPRS technology it is recommended that you use SIM cards with a dedicated tariff plan for M2M machine to machine communication If the programmed PIN code is invalid the module will report a trouble Another attempt to use the PIN code will be made after 4 minutes After...

Page 12: ...trol panel Name individual name of the device up to 16 characters Tamper signaled in part Tamper in part partition where alarm will be triggered in the event of module tamper INT GSM options SIM 1 SIM 2 SIM1 SIM2 if this option is enabled the given SIM card is supported by the module Disable the option if the given card is not to be used Disabling the option will prevent unnecessary reporting of t...

Page 13: ...on can be established between the INTEGRA CONTROL application and the alarm control panel via the module The connection is set up by the SATEL server The option is not available when the INTEGRUM client option is enabled INTEGRUM client INTEGRUM if this option is enabled connection can be established between the INTEGRUM system version 2 0 or newer and the alarm control panel via the module When t...

Page 14: ...k the button to open the window in which the QR code is displayed The QR code contains information required when configuring settings of communication through the SATEL server You can read the QR code by using a mobile device or export to the file and transmit to the users The QR code facilitates configuring the INTEGRA CONTROL application settings Refresh click to refresh all information 5 2 INT ...

Page 15: ...or of GSM network to which the SIM card is to log in Enter in turn MCC Mobile Country Code country code MNC Mobile Network Code operator code Remember that entering invalid data may make logging into the GSM network impossible Unless you enter the code the module will log into the available GSM network auto if this option is enabled and the module cannot log into the network of GSM operator define...

Page 16: ...ng SMS messages through the control panel USSD codes from any number if this option is enabled the control command for sending the USSD codes or checking the SIM card balance see Check balance SMS p 16 can be sent from any telephone If the option is disabled the command can only be sent from the telephone whose number is stored in the module see SMS messaging CLIP control p 16 Time from GSM networ...

Page 17: ...n enter up to 16 alphanumeric characters digits letters and special characters The content of control commands must vary The content of one control command must not be inserted into the content of another command You can include in the SMS message the address of computer the module is to connect to and the number of TCP port to be used for communication Such a message should look like this xxxx aa...

Page 18: ... to a telephone number the control panel can be operated from that telephone by using CLIP and SMS messages Additionally you can indicate a control panel user that will be able to operate the control panel from any telephone number It is advisable to create a control panel user with authority level suited for the SMS CLIP control not for everyday operation of the alarm system The module can send n...

Page 19: ...assigned to the control panel user The telephone numbers programmed in the lines from T1 to T16 are not treated by the module as any numbers Function the function to be run by CLIP Enter the function number or click on the button to select the function from the list The list of available functions is defined in the SMS control tab see Function p 18 Forward SMS SMS if this option is enabled unknown...

Page 20: ...command may be just a fragment of the SMS message This makes it is possible to write the control command including the comments to the telephone memory and send the whole to the module Function function run by the control command received in the SMS message or by CLIP see CLIP control p 17 If you program the function without defining any control command Control SMS field the function can only be r...

Page 21: ...he case the SMS message must look like this xxxxxx a b c d where xxxxxx control command a b c d parameters e g 1 2 3 4 numbers of partitions outputs zones separated with commas For the 15 Trigger zone function the control command must have the following form xxxxxx a where xxxxxx control command a zone number e g 1 you can indicate only one zone 5 2 5 Reporting The module enables the alarm control...

Page 22: ...umber of the monitoring station for SMS reporting SMS format SMS format for SMS reporting It must be defined as required by the monitoring station The SMS message format preset by default in the module corresponds to the default settings of the STAM 2 monitoring station firmware version 1 2 0 or newer for the Contact ID format 5 2 6 Remote firmware update Remote update of the module firmware is ma...

Page 23: ...trol panel If the Update server address in SMS option is enabled and you want the module to connect to an update server other than that indicated in the module settings the message should look like this xxxx aaaa pp xxxx control command aaaa server address IP address or domain name pp port number The module sends out an SMS notification on how the new firmware download has proceeded The notificati...

Page 24: ...ser functions after entering the code and pressing an arrow key Fig 16 DLOADX program User functions definition tab 5 4 Virtual keypad The virtual keypad allows you to operate and program the alarm system in much the same way as using a physical keypad You can use the virtual keypad in the DLOADX and GUARDX programs and in the mobile device after installation of the INTEGRA CONTROL application Par...

Page 25: ... these parameters and options are available for the virtual keypad Fig 17 DLOADX program parameters and options of the virtual keypad available in GUARDX program or mobile device 5 5 Macro commands The INTEGRA CONTROL application allows to control the alarm system by means of macro commands thus making it possible to quickly and easily run a number of different functions by touching just a few key...

Page 26: ...om the module Write click to write the macro command related data to the module Quit click to cancel reading or writing the macro command related data Reset click to delete all the defined macro commands and restore factory default settings 5 5 1 Groups The macro commands which are to be available to the INTEGRA CONTROL application users must be assigned to one of the four groups You can assign up...

Page 27: ... Remove macro click to delete selected macro command Name individual name of the macro command up to 16 characters in two lines up to 8 characters in the line Authorization required if this option is enabled the macro command will only be run after user additional authorization Disabl if armed if this option is enabled the macro command will not be available when any of the partitions operated by ...

Page 28: ...icon will be displayed when the output is inactive and the other when the output is active State follow output if this option is enabled the icon of macro command will change depending on the status of output whose number should be selected in the field on the right side Select an output the status of which depends on the actions taken by the control panel after running the macro command Thus it w...

Page 29: ...e field designated by the partition number Bypass zones select the zones which are to be inhibited double click on the field designated by the zone number Unbypass zones select the zones which are to be unbypassed double click on the field designated by the zone number Outputs ON select the outputs which are to be activated double click on the field designated by the output number Outputs OFF sele...

Page 30: ...he zones must not have the Bypass disabled option enabled The outputs must be the 24 MONO SWITCH 25 BI SWITCH 105 SHUTTER UP 106 SHUTTER DOWN or REMOTE SWITCH type The INTEGRA CONTROL application can control the KNX system if the INT KNX or INT KNX 2 module is connected to the control panel 5 5 3 Defining the macro commands 1 Click the Read button to read the macro command related data from the mo...

Page 31: ...tion 6 If the macro command is to be unavailable when any of the partitions managed by the application is armed enable the Disabl if armed option 7 If the macro command is to be available without entering the group enable the Autoexecute option 8 If the confirmation messages are not to be displayed after running the macro command enable the No confirmation messages option ...

Page 32: ...on is to change depending on the selected output state enable the State follow output option indicate the output number select the icons 11 If the macro command name is to be displayed enable the Show name option 12 Click the button and select the function the new macro command is to execute ...

Page 33: ...appear on the list of commands assigned to the macro command You can still modify parameters of the command after clicking on it having made the changes click the Change button 15 Repeat the steps 12 14 if you want to add next commands 16 Click the Groups tab 17 Click on the group you want to edit ...

Page 34: ...on for the macro command group 20 Click the Add macro button A list of all defined macro commands will be displayed 21 Click on a macro command to add it to the group The macro command will be put in the tree under the group 22 Click the Write button to write the macro command related data to the module ...

Page 35: ...gram must have a public IP address 3 Establishing connection via the SATEL server The alarm system can be managed from any location No public IP address is required for the computer with GUARDX program Connection can be established if the identifiers programmed in the control panel and the GUARDX program are identical INTEGRA identifier and GUARDX identifier Required settings of the INT GSM module...

Page 36: ...the control panel and the computer with GUARDX Click on to show the number entered Fig 22 GUARDX program TCP IP tab in Connection window Satel sever tab The settings below apply to communication via the SATEL server Select the INT GSM IMEI variant INT GSM IMEI individual ID number of the GSM telephone of module INT GSM ID individual ID number assigned to the INT GSM module by the SATEL server GUAR...

Page 37: ...ARDX program the module is to connect to the computer address programmed in the module xxxx aaaa p xxxx the control command to initiate establishment of communication with GUARDX program aaaa address of the computer with GUARDX program IP address or domain name p TCP port the module is to connect to the computer whose address has been given in the SMS message and use for communication the TCP port...

Page 38: ...m devices or App Store iOS system devices On the www satel eu website you will find links to the locations from which the applications can be downloaded The INTEGRA CONTROL application makes it possible to establish connection via the SATEL server Connection Setup Service If the INT GSM module is connected to the ETHM 1 Plus module communication via the INT GSM module via GPRS will only be used if...

Page 39: ...cation settings from the QR code see p 12 If the communication settings are configured in one mobile device you can easily copy them to another mobile device You just need to display the QR code on the device in which the settings for communication with the given module are already configured and read it on another device Manual configuration 1 Tap on the screen in the Communication way area to se...

Page 40: ... the application for the first time the Systems tab will be displayed 1 Tap Edit 2 Tap New 3 Enter the name for alarm system The name helps to identify the system when the application is in use you can define settings for multiple alarm systems 4 Configure settings for communication with the INT GSM module The settings can be configured automatically see Automatic configuration QR code p 39 or you...

Page 41: ...een before entering data Automatic configuration QR code Tap to start QR code scanner Using the scanner read the communication settings from the QR code see p 12 If the communication settings are configured in one mobile device you can easily copy them to another mobile device You just need to display the QR code on the device in which the settings for communication with the given module are alrea...

Page 42: ...hone 3 Enter the ID number of the INT GSM module assigned to the module by the SATEL server The user can use keypad to check the IMEI and ID numbers IP MAC IMEI ID user function is available in the TESTS submenu see the control panel user manual 4 Enter the data encryption key identical to that in the module GUARDX key 6 2 3 Establishing the communication Tap the name of the alarm system The virtu...

Page 43: ... keypad 7 Specifications Supply voltage 12 V DC 15 Standby current consumption 130 mA Maximum current consumption 250 mA Environmental class according to EN50130 5 II Operating temperature range 10 55 C Maximum humidity 93 3 Electronics board dimensions 80 x 57 mm Weight 38 g ...