
Page 53
Press the ENTER key to move the underscore to the right and press the key to move the underscore to the left.
FUncTiOn PagE F3
When entering a character in a position occupied by a space, a group can be selected from the preceding character by first
pressing the DEC/- key. This is useful when entering several characters from the same group.
2) Press the INC/+ or DEC/- keys to select a character, then
press the ENTER key to advance the underscore to the
next space.
3) Repeat the previous procedure to enter the desired
remaining characters.
A group of character styles can be selected by pressing the INC/+ and DEC/- keys at the same time. Choose from capital
letters, lower case letters, symbols, higher case numerals, and lower case numerals.
To erase a character, move the underscore under the character you want to erase, then press the INC/+ and DEC/- keys at
the same time until the single dark block (Erase Block) is selected. The underlined character will automatically be erased.
The Fail Safe function automatically sets the servos to a predetermined position in the
event that the signal between the transmitter and the receiver is interrupted, whether
due to signal degradation or to low transmitter battery voltage. Several different
setting options are available. The Fail Safe function can be set to Hold the servos in the
last position they were in when the signal was lost, or each of the servos can be set to
move to a custom position when the signal is lost. For example, the throttle servo moves to the Brake side to engage the brakes
and stop your model. If you're driving a gas- or glow-powered boat, the Fail Safe function could be set to lower the throttle to idle
and turn the rudder slightly left or right, so that the boat will continue in slow circles.
In addition, a Receiver Battery Voltage Fail Safe function allows you to set a custom receiver voltage, that when reached, will
Activate only the Throttle channel Fail Safe programming.
Function Page 3 (F-SAFE)
Fail Safe settings can be programmed for each of the four channels individually.
FREE
- The Fail Safe function is disabled for this channel.
HOLD
- When the Fail Safe function Activates, the servo will be held in the last position it was in when the signal was lost.
FS
- When the Fail Safe function Activates, the servo will move to a predetermined position when the signal is lost. We
highly recommend this setting for most users.
Choosing a Fail Safe Setting
1) Press the Function key to highlight the F-SAFE menu. [FAIL SAFE] will be
Active in the Programming Window and the cursor will default to ST.
2) Press the ENTER key to move the cursor to TH, then press the INC/+
or DEC/- keys to set the desired TH value. Choose from the values
described below.
The Fail Safe settings will be retained even if the transmitter loses power or if the transmitter and receiver must be paired
again.
F-SaFE (FaiL SaFE)
[FAIL SAFE] FAIL SAFE SETTING
IMPORTANT
The Fail Safe function will only work if the signal between the transmitter and receiver is interrupted or if the
transmitter loses power. The Fail Safe function will NOT work if the receiver loses power (e.g., the receiver battery is drained,
the receiver battery comes unplugged, etc.)
FuNCTION P
AGE F3
Summary of Contents for ExzesX
Page 1: ...Page 1 ...