GUIDE TO THE
REGENERATIVE APPLICATION
SINUS PENTA
45/
150
3.9.5. UL-approved Fuses
– Class 4T
UL-approved semiconductor fuses
,
which
are recommended for the drives of the SINUS PENTA series,
are listed in the table below.
In multiple cable installations, install one fuse per phase (NOT one fuse per conductor).
Fuses suitable for the protection of semiconductors produced by other manufacturers may be used, provided
that they have the same or better ratings and
are Nonrenewable UL Listed Cartridge Fuses, or UL Recognized External Semiconductor Fuses;
are of the type specifically approved also with reference to the Canadian Standard.
Siz
e
M
od
e
l
S
INUS
PENTA
RE
G
ENER
ATIVE
UL-approved Fuses Manufactured by:
SIBA Sicherungen-Bau GmbH
(200 kA
RMS
Symmetrical A.I.C.)
Bussmann Div Cooper (UK) Ltd
(100/200 kA
RMS
Symmetrical A.I.C.)
Q.ty
Mod. N.
Ratings
Q.ty
Mod. N.
Ratings
A
RMS
Current
I
2
t (500V)
A
2
s
Vac
A
RMS
Current
I
2
t (500V)
A
2
s
Va
c
S05
0005
1
50 142 06 16
16
40
700
1
170M1409
16
36
700
0007
0009
1
50 142 06 25
25
105
1
170M1410
20
58
0011
0014
1
50 142 06 40
40
450
1
FWP-40B
40
160
S12
0016
1
50 142 06 40
40
0017
0020
0025
1
20 412 20 63
63
980
1
FWP-60B
60
475
0030
0034
1
20 412 20 80
80
1.82k
1
FWP-80B
80
1.20k
0036
S15
0040
1
20 412 20 100
100
2.80k
1
FWP-100B
100
1.75k
0049
S20
0060
1
20 412 20 125
125
5.04k
0067
1
FWP-125A
125
5.40k
0074
1
20 412 20 160
160
10.78k
1
FWP-150A
150
8.70k
0086
1
20 412 20 200
200
19.25k
1
FWP-175A
175
12.3k
S30
0113
1
20 412 20 250
250
32.76k
1
FWP-225A
225
23.0k
0129
0150
1
20 412 20 315
315
60.20k
1
FWP-250A
250
32.0k
0162
1
20 412 20 400
400
109.2k
1
FWP-350A
350
70.8k