GUIDE TO THE
REGENERATIVE APPLICATION
SINUS PENTA
95/
150
M568 RMS Voltage, Phase S
M568
Range
32000
3200.0V
Address
1718
Function
Root mean square of the line voltage in phase S.
M573 RMS Current, Phase S
M573
Range
32000
3200.0A
Address
1723
Function
Root mean square of the line current in phase S.
M574 Active Power, Phase T
M574
Range
32000
3200.0kW
Address
1724
Function
Active Power in phase T.
M575 Reactive Power, Phase T
M575
Range
32000
320.00 kVAR
Address
1725
Function
Reactive Power in phase T.
M576 Apparent Power, Phase T
M576
Range
32000
3200.0kVA
Address
1726
Function
Apparent Power in phase T.
M577 Power Factor, Phase T
M577
Range
100
1.00
Address
1727
Function
Power factor in phase T (ratio between the Active Power and the
Apparent Power).
M578 RMS Voltage, Phase T
M578
Range
32000
3200.0V
Address
1728
Function
Root mean square of the line voltage in phase T.
M579 RMS Current, Phase T
M579
Range
32000
3200.0A
Address
1729
Function
Root mean square of the line current in phase T.