AFG-31000 Series Instruction Manual/English
264
22/11/2016 Version No. 002
Note
The function generator will not output more than ±5V, regardless of
the modulation depth.
The modulation depth of an external source is controlled using the
±5V MOD INPUT terminal on the rear panel, and not the
SOURce[1]:AM:DEPTh command.
Syntax
SOURce[1]:AM:DEPTh {<depth in percent> |MINimum|MAXimum}
Parameter
<depth in percent>
0~120%
Example
SOUR1:AM:DEPT 50
Sets the modulation depth to 50%.
Query Syntax
SOURce[1]:AM:DEPTh? [MINimum|MAXimum]
Return Parameter
<NR3>
Return the modulation depth as a
percentage.
Example
SOUR1:AM:DEPT?
+1.0000E+02
The modulation depth is 100%.
Summary of Contents for AFG-31000 Series
Page 1: ...Instruction Manual AFG 31000 Series Arbitrary Function Generator EN FR DE IT SP ...
Page 2: ......
Page 80: ...AFG 31000 Series Instruction Manual English 78 22 11 2016 Version No 002 ...
Page 112: ...AFG 31000 Series Instruction Manual English 110 22 11 2016 Version No 002 ...
Page 139: ...MODULATION 22 11 2016 Version No 002 137 ...
Page 149: ...SECONDARY SYSTEM FUNCTION SETTINGS 22 11 2016 Version No 002 147 ...
Page 157: ...SECONDARY SYSTEM FUNCTION SETTINGS 22 11 2016 Version No 002 155 ...
Page 167: ...ARBITRARY WAVEFORMS 22 11 2016 Version No 002 165 ...
Page 178: ...AFG 31000 Series Instruction Manual English 176 22 11 2016 Version No 002 ...
Page 181: ...ARBITRARY WAVEFORMS 22 11 2016 Version No 002 179 ...
Page 183: ...ARBITRARY WAVEFORMS 22 11 2016 Version No 002 181 ...
Page 185: ...ARBITRARY WAVEFORMS 22 11 2016 Version No 002 183 ...
Page 210: ...AFG 31000 Series Instruction Manual English 208 22 11 2016 Version No 002 ...
Page 219: ...REMOTE INTERFACE 22 11 2016 Version No 002 217 ...
Page 339: ...REMOTE INTERFACE 22 11 2016 Version No 002 337 ...
Page 360: ...AFG 31000 Series Instruction Manual English 358 22 11 2016 Version No 002 Warning symbol 4 ...