Instalattion and operating manual: MGSM 5.0/MGSM 5.0-PS v.1.8S EN
7
.3. Remote configuration of OUTPUTS
The configuration SMS syntax has the following format:
yyyy Ox [parameter1 parameter2 parameter3 parameter4]
Where:
- yyyy = access code, Ox = output with the no. x = {1..3}
Parameter
Description
Example
Remarks
NO
NC
Input polarization
(see paragraph 6.4.1)
NO
MONO
BI
Output operation mode
(see paragraph 6.4.1)
MONO
TIME tttt
The time of output operation in
MONO mode
TIME 1500
tttt = time in seconds [s]
Maximum time is 9,000s
ACTIV
xxxxxxxxxxx
The mask for activating the
output, according to the
ACTIVATE VIA tab and the
sequence: SMS, CLIP, ALARM,
armed, TIME FOR ENTRY, TIME
FOR EXIT, ARMING
CONFIRMATION BY IMPULSES,
INPUT VIOLATION, FAILURE,
NO AC SUPPLY, SABOTAGE
ACTIV
11000000010
00
x = 1 option active
x = 0 option inactive
- Marking a few options
results in output activation
according to the selected
logical function (the logical
function OR – factory
settings)
SMSON “aaaa”
The content of the SMS
message which activates a
particular output
SMSON
“pump on”
“aaaa” = maximum 20
characters
SMSOFF “aaaa”
The content of the SMS
message which deactivates a
particular output
SMSOFF
“pump off”
“aaaa” = maximum 20
characters
CLIP xxxxxxxxx
The mask of the numbers
authorized to perform CLIP
control of a particular output
(the sequence xxxxxxxxxxx =
TEL1…TEL8… EACH)
CLIP
110000000
x = 1 control is active
x = 0 control is blocked
Example:
yyyy O1 NO MONO TIME 100 ACTIVE 11000001000
yyyy = access code
7.4. Remote configuration of TRANSMISSION TEST.
The configuration SMS syntax has the following format:
yyyy TEST [parameter1 parameter2 parameter3.......]
Where:
- yyyy = access code;
Parameter
Description (see
paragraph 6.5.1)
Example
Remarks
ON
OFF
Activation of the transmission
test option only
(see paragraph 6.5.1)
ON
CLIP
Altering the transmission test
type to CLIP
(see paragraph 6.5.1)
CLIP
- After the activation of
transmission test, the type is
set to SMS sending by default
42