Instalattion and operating manual: MGSM 5.0/MGSM 5.0-PS v.1.8S EN
5.2. “PARTNER GSM” COMMUNNICATION WITH THE MGSM 5.0/5.0-PS
5.2.2 LOCAL CONFIGURATION VIA RS 232TTL (PC: RS232, USB)
The MGSM 5.0/5.0-PS module is configured via the RS 232 TTL interface. To enter the
configuration process, the following actions should be performed:
1. Switch off the module power supply.
2. Connect the communication cable to the RS 232 connector on the module board.
3. Connect the cable to the service computer port (options: RS 232 or USB).
4. Start the service computer and the PARTNER GSM software.
5. Switch on the module power supply.
6. In the PARTNER GSM software:
6a.Enter the PASSWORD in COMMUNICATION OPTIONS
(factory password: 123B);
6b.Select the COM port number and open it; the state of ”waiting to be connected
with the module” is signalized by a message in the footnote: WAITING FOR
MODULE RESPONSE or
6c. The ”AUTO-DETECT COM” option must be marked.
Open the COM port and start procedure no.7 (press the PR switch) the PARTNER
GSM starting procedure : 'AUTOSCAN' active COM ports ( two rounds).
7. Press the PR switch (ca. 1 second), yellow SEND diode flashes.
8.
The module communication should be initiated – the communication options should become
visible. Furthermore, the functioning communication is signalzied by the flashing „light” next
to the port number
and the COMMUNICATION ESTABLISHED message is
displayed in the PARTNER GSM software footnote, together with the device type, modem and
module firmware version number.
9.
Configure the module, perform (ON-LINE) tests etc.
During the read/write etc. this is signalled with an appropriate message in the program
footnote by a fractional indicator.
10. To end the communication, press the PR switch (the yellow SEND LED will flash 4-5 times).
11. Disconnect the cable from the RS 232TTL connector.
12. Perform tests and user training.
5.2.2 REMOTE CONFIGURATION VIA MODEM CONNECTION (CSD)
In the local connection mode for MGSM 5.0/5.0-PS module (via RS232 – see: Local Configuration),
it is possible to establish a modem connection with another module. In
order to establish a
modem connection, follow these steps:
1.
Enter
the PASSWORD in the COMMUNICATION OPTIONS
(factory password: 123B)
The password must be identical to the password in the MGSM 5.0 /5.0-PS remote
module and the MODEM ACCESS option must be programmed.
2. Click the MODEM CONNECTION icon.
3.
The correct list of modem connection sessions will be confirmed by an appropriate message.
14