Instalattion and operating manual: MGSM 5.0/MGSM 5.0-PS v.1.8S EN
•
module power supply voltage
•
access to control SMS sending option (simulation of test SMS)
6.6.6 MONITORING OF INPUT STATES
The input states are displayed on round indicators mounted in places of screws securing
module connectors. The state of each input is signaled by the color of the indicator:
RED – input violated
GREEN – input not violated
YELLOW- input tampered (sabotaged)
Remarks:
●
ON-LINE monitoring requires an active connection via RS232TTL
6.6.7 MONITORING OF OUTPUT STATES
The activation of module outputs is possible by using this option. An initial test of the
signaling device without starting the alarm procedure is possible. To trigger a given output
(in accordance with the polarity set in the OUTPUTS bookmark), the white indicator mounted
in the place of screws securing the module connector (physically in the place of the
connector associated with the module output), should be marked by clicking the mouse
button on it. After clicking on it, the
„√ ”
character signifying the input activation will be
displayed. A second click will mark the indicator and switch the activation off.
6.6.8 ENTER PIN CODE
Pressing ENTER PIN CODE, will cause that a PIN code (which is currently displayed in the SIM
CARD PIN CODE field) entering command is sent to the module telephone.
Testing modules containing SIM cards which belong to different operators, without the
necessity of configuration changing and it’s recording, is possible by using this option. The
configuration entered in the MGSM module, must have marked the option PIN CODE NOT
33