CODE REQUIRED
Marking this option, in order to control a particular output with SMS messages, will require
providing an ACCESS CODE (OPTIONS tab) in the SMS message content, as an addition to
the SMS ON/SMS OFF content.
●
CODE
DTMF ON
In the tap we enter DTMF code (figures) which will cause switching on a particular output in
DTMF control mode (during connection: code DTMF ON + [*]). The code may consist of 2 to
4 figures.
●
CODE
DTMF OFF
In the tap we enter DTMF code (figures) which will cause switching off a particular output
in DTMF control mode (during connection: code DTMF OFF + [*]). The code may consist of 2
to 4 figures.
•
SWITCHING VIA
•
SMS,
output control via SMS (c code) is permitted when option is marked
•
CLIP
, output control by making a short connection with the module telephone number.
The function is accessible when control is enabled by selecting numbers entered in the
“Telephone numbers” fields in the “Numbers authorized to control CLIP” panel, or by
entering any number. In addition, the module reaction to incoming calls can be defined by
using the “Incoming calls” option
•
ALARM
output is active when alarm is triggered. (def. normal input)
•
ARMED
output active (indicator) armed when module counter has finished countdown
time to exit. When this option is active, the settings in the “
TIME [s]
” field are ignored.
•
ENTRY TIME
, output is active during module entry countdown time (def. ARM/DISARM
input, delayed)
•
EXIT TIME
output active during module exit countdown time
•
IMPULSE ARMING ACKNOWLEDGEMENT
option activates ARM/DISARM module
standby time acknowledgement. Function available only for O1 output.
Signaling: 1 short signal – standby on, 2 short signals: standby off.
•
INPUT/OUTPUT VIOLATION
– the output is active when the input is violated or output
activated. The mask for the inputs/outputs, which activate a particular output, can be
configured in the ACTIVATING INPUTS/OUTPUTS.
•
FAILURE
– the output is activated after a failure has occurred.
•
NO AC
– the output is activated after a decay in the AC supply has occurred (MGSM 5.0-
PS only), the time of delay for signaling “no AC supply” (5s – 1,000 min) is configured in
the OPTIONS tab.
•
TAMPER
– the output is activated when the 2EOL/NC or 2EOL/NO line has been
sabotaged.
•
DTMF marking th option allows controlling the output with DTMF codes (DTMF ON –
switches on the output, DTMF OFF – switches off the output)
6.4.2 CLIP CONTROL TELEPHONES
Marking this option authorizes the telephone numbers entered in the NUMBERS tab to control
the output with the ACTIVATE VIA CLIP option marked. Selecting this option makes EVERY module
to control the output when connecting via any telephone number.