Instalattion and operating manual: MGSM 5.0/MGSM 5.0-PS v.1.8S EN
6.4.1 OUTPUTS - OPTIONS
•
POLARITY
Choice of configuration in normal mode:
- open NO or shorten NC to the module „plus”:
O1
output,
-
open NO or shorten NC to the module „mass”: outputs
O2, O3, O4
•
OPERATION
MONO -
output changes the normal mode after the event marked in the “Switched on by”
field for a duration of time specified in the “Time [s]” field, and after it elapses, it restores to
normal mode
BI -
output changes the normal mode after the event marked in the “Switched on by” field to
the opposite mode and remains in it until the next event.
•
TIME [s]
Determines operation time [s] in the output MONO mode, where the maximum time duration
is 9000 seconds.
●
SMS ON
Enter the SMS message content in the tab. The content will cause the activation of the given
output (On X by default, where X = output number). The maximum length of the SMS
message is 20 characters. Do not use special characters (for example: letters of the local
alphabet).
●
SMS OFF
Enter the SMS message content in the tab. The content will cause deactivation of the given
output (OffX by default, where X = output number). The maximum length of the SMS
message is 20 characters. Do not use special characters (for example: letters of the local
alphabet).
23