Instalattion and operating manual: MGSM 5.0/MGSM 5.0-PS v.1.8S EN
number of sent SMS alarm and information messages during one day.
Set the number in the range 1-99.
•
FAILURE COUNTER
– determines the maximum number of sent SMS messages
containing information about failures (e.g. during the PSR-RF cooperation), during one
day.
Set the number in the range 1-20.
•
THE NUMBER OF SMS SENDING ATTEMPTS
– determines the number of SMS
message sending attempts when transmission problems are encountered (e.g. temporary
loss of GSM signal level). Set the number in the range 1-10.
•
DIAL ROUND COUNT –
determines the number of telephone connections to each
telephone number entered in the NUMBERS bookmark.
Set the number in the range 1-10.
Remarks:
●
The SMS COUNTER is reset also after execution of the SMS RESETTEST.
●
The SMS and FALURE counter operates independently i.e. SMS messages
regarding failures are not counted by the SMS counter and vice versa.
6.5.4 TIMES
Telephone connection time, CLIP signal time,
waiting time for SMS sending, entry and exit time for
ARM/DISARM and DELAYED inputs can be set in this
bookmark.
•
CALL TIME [s]
– determines maximum
duration of telephone (voice)
connection. Time is measured from the
moment of call received detection.
Set the number of seconds in the range
1-64.
•
ENTRY TIME [s]
– determines the maximum entry time counted from the moment of
DELAYED type input entry violation. Set the number of seconds in the range 1-600.
•
EXIT TIME [s]
– determines the maximum standby switch on time delay (NORMAL
type of inputs) after ARM/DISARM input violation. Set the number of seconds in the
range 1-600.
•
CLIP TIME [s]
– determines the maximum waiting time for the connection. CLIP time
is 3-5 seconds from receiving the call detection moment.
The maximum time for connection establishment is 20 seconds.
•
WAITING TIME FOR SMS SENDING [s]
– determines module waiting time for
correct SMS sending acknowledgement. When no acknowledgement is received in the
set time, the module will make attempts as many times as set in NUMBER OF SET
SMS SEND ATTEMPTS.
6.5.5 SMS COMMANDS
In this bookmark the ACCESS CODE for the following can be entered:
•
module output control
•
configuration change of chosen module
functions.
The access code must contain four characters. Only alphanumeric characters are allowed.
29