Instalattion and operating manual: MGSM 5.0/MGSM 5.0-PS v.1.8S EN
DELAYED input (for the alarm
control panel function)
EXIT xx
The parameter determines the
time of exiting for the alarm
control panel function
EXIT 30
xx = a number between 1
and 600 seconds
ACLOST xxx
The parameter determines the
time of delay for signaling “no
AC supply”
ACLOST 060
xxx = a number between 0
and 999 minutes
ex.
yyyy TIME OF CALL 40 ENTRY 15 EXIT 3 ACLOST 060
yyyy = access code
7.7. Remote configuration of other parameters.
The configuration SMS syntax has the following format:
Where: yyyy = access code;
Parameter
Description
Example
Remarks
yyyy CODE zzzz
Altering the access code
(zzzz = new access
code)
1111 CODE 1234
yyyy = present access
code
zzzz = new access
code
yyyy TIME yy, mm, dd,
hh, mm
Setting, altering of date
and time (yy, mm, dd,
hh, mm = year, month,
day, hour, minutes)
1111 TIME 02, 01,
01, 12, 05
Gap (space) required
after commas
yyyy CORRECTION qsss
Correction of module
clock
(q = +/- character, sss
= correction value [s])
1111 CORRECTION
-002
q= +/-
sss = max. 120[s]
yyyy RESETTEST
Resetting of the
transmission test clock
1111 RESETTEST
yyyy RESTART
Restarting of modem
and module
1111 RESTART
yyyy DOWNLOADING x
Remote
activation/deactivation
of the modem
connection function
1111 DOWNLOADING
1
X = 1 function
enabled
x = 0 function
disabled
yyyy REPLYSMS x
Remote
activation/deactivation
of the modem reply
function (after receiving
SMS commends
1111 DOWNLOADING
1
X = 1 function
enabled
x = 0 function
disabled
44