4-52
Turn on the sub power switch while pressing [ ], [ ]
and [ ] keys to enter the SERVICE MODE.
1
2
3
SERVICE MENU
[ ] , [ ] , [ ] + SUB POWER ON
[MENU] key
MENU
[ ]
SERVICE MENU
CUTTING MENU
CUTTING MENU
PRINT-CUT ADJ.
PRINT-CUT ADJ.
TEST PRINT 2
[ ]
[ ]
[ ]
[ ]
PRINT MENU
HEAD ADJUST
HEAD ADJUST
BI-DIR.DEFAULT
[ ]
SERVICE MENU
PRINT MENU
[ ] [ ]
[ ]
[ ]
4-11 PRINT / CUT POSITION ADJUSTMENT (Referential Time : 10min.)
This adjustment is for calibrating the relative positions of printing and cutting. If it is not adjusted, it
may result in the mis-alignment of the printing and cutting.
This adjustment is required when Crop Mark Sensor, Tool Carriage or Print Head is replaced or
adjusted, and also when the relative distance between Tool and Print Head is changed.
Before this adjustment, it is necessary to confirm that [ENABLE] is selected for [AUTO ENV.
MATCH].
Also, Take-up unit must not be used during this adjustment.
Select [TEST PRINT 2] under the [PRINT-CUT ADJ.]
menu.
Press [ENTER] key to start the test print.
Perform BI-DIRECTION ADJUSTMENT.
After the adjustment, leave the PET-G on the printer to
use continuously for this PRINT/CUT POSITION
ADJUSTMENT.