4-49
Turn on the sub power switch while pressing [ ], [ ]
and [ ] keys to enter the SERVICE MODE.
1
3
SERVICE MENU
[ ] , [ ] , [ ] + SUB POWER ON
[MENU] key
MENU
[ ]
SERVICE MENU
CUTTING MENU
CUTTING MENU
CROP-CUT ADJ.
CROP-CUT ADJ.
TEST PRINT 2
[ ]
[ ]
[ ]
[ ]
2
PRINT MENU
HEAD ADJUST
HEAD ADJUST
BI-DIR.DEFAULT
[ ]
SERVICE MENU
PRINT MENU
[ ] [ ]
[ ]
[ ]
4-10 CROP-CUT ADJUSTMENT (Referential Time : 10min.)
This adjustment is for calibrating the relative positions of Tool and Crop Mark Sensor. If it is not
adjusted, the cutting position based on the detected Crop Marks becomes wrong, and that results
in the mis-alignment of the Print and Cut when performing the auto crop mark detection.
This adjustment is required when Crop Mark Sensor or Tool Carriage is replaced or adjusted.
Before this adjustment, it is necessary to confirm that [ENABLE] is selected for [AUTO
ENV. MATCH].
Also, Take-up unit must not be used during this adjustment.
Select [TEST PRINT 2] under the [CROP-CUT ADJ.]
menu.
Press [ENTER] key to start the test print.
Perform BI-DIRECTION ADJUSTMENT.
After the adjustment, leave the PET-G on the printer to
use continuously for this CROP-CUT ADJUSTMENT.