![Roland SOLJET Pro III XC-540 Service Notes Download Page 107](http://html1.mh-extra.com/html/roland/soljet-pro-iii-xc-540/soljet-pro-iii-xc-540_service-notes_1481427107.webp)
3-45
2
Disconnect all the cables connected to the SW Power
Supply.
SW POWER SUPPLY REPLACEMENT (41V)
SW POWER SUPPLY CONNECTOR LAYOUT
3
Remove the 4 screws as shown in the figure and replace
the new SW Power Supply (41V).
Connected to the [CN301]
on the AC Junction Board
Connected to the [CN800]
on the DC Junction Board
1
Disconnect the Cables from the following boards and
remove them with the Stays.
HEATER BOARD
SERVO BOARD
MAIN BOARD
HEAD BOARD
Heater
Board
Servo Board
Main Board
Head Board
Revised 1