4-27
1
2
3
4-5 HEAD ALIGNMENT (Referential Time : 30 min._1 Head Alignment)
[About HEAD ALIGNMENT]
HEAD ALIGNMENT is necessary to obtain the good printing quality.
Be sure to operate the HEAD ALIGNMENT when the HEAD is replaced.
If the heads are not aligned, printing problems such as banding, fine lines and gap between bands could occur.
Please DO NOT use Take-Up devise for this alignment.
The media tension changes during test printing and the result of alignment is not reliable.
Remove the FRONT COVER, RIGHT I/S COVER and
INNER I/S COVER.
Remove the CARRIAGE COVER, removing the 4 screws
shown in the figure.
FRONT COVER
RIGHT I/S COVER
RIGHT INNER PLATE
CARRIAGE COVER
Holes on TOP COVER
There are 2 holes on the TOP COVER.
Upper 2 screws can be removed inserting a
screwdriver through the TOP COVER.
Remove the DAMPER PLATE, removing the 2 screws
shown in the figure.
DAMPER PLATE
SCREWS
RIGHT INNER PLATE has a small hook on its
right bottom and it is inserted to the lower
cover. Be cautious when removing it.
REVISED 3