3-61
6
7
Disconnect the flexible cable connected to the CN13 on
the Servo Board.
5
Remove the Encoder Scale by removing the Plate fixing
the Encoder Scale at its right end and the Spring on its
left end.
Spring Encoder Scale
Encoder Plate Plate
Turn off the Main Power SW and pull out the power cord.
And remove the Board Cover.
Main Power SW
< Rear view >
Board Cover
Remove the 2 Cable Holders that are holding the Flexible
Cable on the Rail, and remove the rivets that are fixing
the Cable Guides.
Cable Holder ( left ) Cable Holder (right )
Cable Guide
8
Remove the Encoder Scale to protect.
Because there is a possibility to scratch or put
grease on the Encoder Scale when replacing
the Flexible Cable.