Manual
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
System description
B0063191 / 1.3
10
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
2.2
Sensor system LAAS40
Technical data
Application:
Double Sheet Control
Material thickness:
0.3 - 15 mm (at nominal sensor distance Ax = 40 mm)
Repetition accuracy:
+/- 0.05 mm
Measuring principle:
Laser triangulation, Laser Class 2, EN 60825-1
Class of protection:
IP54
Weight:
approx. 2 kg (4.409 lbs) – without mounting angle and alignment aid
Material of enclosure: Aluminum
Sensor cable:
Each pluggable with 0.5 m (19.68 in) length
Air connection:
Tube, 8 mm outer diameter
2.3
Sensor system
Technical data
Application:
Double Sheet Control
Material thickness:
0.3 - 15 mm (at nominal sensor distance Ax = 40 mm)
Repetition accuracy:
+/- 0.05 mm
Measuring principle:
Laser triangulation, Laser Class 2, EN 60825-1
Class of protection:
IP54
Weight:
approx. 2.2 kg (4.85 lbs) – without mounting angle and alignment aid
Material of enclosure: Aluminum
Sensor cable:
Each pluggable with 0.5 m (19.68 in) length
Air connection:
Tube, 8 mm outer diameter
Beam control:
Photo element
2.4
Sensor cable
Cable marking:
SCL20S-GG
with straight cable socket at the sensor and straight cable plug at the unit
Technical data
Cable length:
From 0.5 m to 50 m, pluggable
Cable bending radius:
50 mm at fixed wiring; 100 mm at flexible wiring
Cable diameter:
7.1 mm
Suitable for drag chains, oil proof, PUR jacket; Superflex TRONIC[C]PUR TP 4 x 2 x 0.25 mm²
2.5
Beam control cable
Cable marking:
SC5M12S-GG
with straight cable socket at the sensor and straight cable plug at the unit
Technical data
Cable length:
From 0.5 m to 50 m, pluggable
Cable bending radius:
50 mm at fixed wiring; 100 mm at flexible wiring
Cable diameter:
5.3 mm
Suitable for drag chains, oil proof, PUR jacket; Superflex TRONIC[C] UL 5 x 0.25 mm²