Manual
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
B0063191 / 1.3
Start-up
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
89
System parameter 14:
Adjusting the measuring mode.
Fig. 78: Adjusting the measuring mode
Possible measurement modes:
•
external single:
The system measures
once
if the “Measurement start“ signal is applied.
Each measurement must be initiated separately. The notes in chapter
6.3.2 „timing diagram single measurement“ must be observed.
•
demonstration:
This mode of operation is intended for equipment demonstrations, but
not for normal process operation. The system executes measurements
continuously.
•
external continuous:
The system executes measurements, as long as
the “Measurement start“ signal is applied.
external special:
As for “external continuous”, but: The highest value reached during a
measurement cycle is displayed and maintained at the outputs until a
new measurement is started.
This also applies for the outputs 0-1-2-Warning.
System parameter 15:
Specifying the system reaction when 2-sheet is detected.
Fig. 79: Adjusting the 2-sheet reaction
Selectable options:
•
no:
The outputs (0-sheet, 1-sheet and 2-sheet) are activated according to the number of
sheets between the sensors. The equipment does not block operation if double
sheet is encountered.
•
yes:
The outputs (0-sheet, 1-sheet and 2-sheet) are activated according to the number of
sheets between the sensors. If double sheet is detected, the output “2-sheet“ is
activated and the equipment is blocked until the 2-sheet condition is cleared.
system parameter: 14
measuring mode
external continuous
system parameter: 15
stop if 2-sheet
no