Double Sheet Control System R1000 series L20
with integrated fieldbus interface
Communication with the PLC
B0063191 / 1.3
64
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
6.6.6 EDS file for EtherNet/IP
The EDS file contains the specific configuration data of the device. The data must be known to the
controller.
The manufacturers of the controller supply the tools for the integration of the EDS file into the
network. Roland Electronic does not supply such tools, because they have to be compatible with
the interface design of the controller.
The EDS file is supplied on a CD or can be downloaded from the Roland homepage.
Note
24 Bytes I/O must be set.
By pressing the key “
▼
” status indicators are shown on the display.
Status Indicators
Nr.
LED
State
Description
LED 1 Link (Activity) LED configuration 1 (Default)
Off
Link not sensed
Green Link
sensed
LED 2 Module
Status
LED configuration 3 (Default)
Off No
power
Green
Controlled by a scanner in Run state
Green, flashing
Not controlled, or scanner in Idle state
Red, flashing
A minor recoverable fault has been detected
Red
A major unrecoverable fault has been detected
Alternating
Red / Green
Self test in progress
LED 3 Network
Status
LED configuration 3 (Default)
Off
No power or no IP address
Green
On line, one or more connections established
(CIP Class 1 or 3)
Green, flashing
On line, no connections established
Red
Duplicate IP address, fatal error
Red, flashing
One or more connections timed out
(CIP Class 1 or 3)
Alternating
Red / Green
Self-test in progress
LED 4 Activity
Status
Green, flashing
The activity led flashes green each time a packet
is received or transmitted