Manual
Double Sheet Control System R1000 series L20
with integrated fieldbus interface
B0063191 / 1.3
Technical records
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
115
Byte 0
Byte 1
Byte 2 Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Command
Direction
of data
Management
Program
index
Parame
ter
index
User
data
byte 0
User
data
byte 1
User
data
byte 2
User
data
byte 3
Check
sum
Range of values
Write system parame
te
r
Default Moving
average
PLC
L20
0H110010
FFh
0Ah
00h 00h 00h LByte XXh
0
=
250
ms;
1 = 100 ms;
2 = 50 ms;
3 = 25 ms;
4 = 15 ms;
2 = 8 ms;
PLC
L20
0H110010
0Ah
00h
00h
00h
LByte
XXh
User data as sent
Reserved
PLC
L20
0H110010
0Bh
00h
00h
00h
00h
LByte 0
PLC
L20
0H110010
0Bh
00h
00h
00h
00h
XXh
User data as sent
Measuring mode
PLC
L20
0H110010
0Ch
00h
00h
00h
LByte
XXh
0 = ext. single measurement
1 = demo operation
2 = ext continuous meas.
3 = ext. special
PLC
L20
0H110010
0Ch
00h
00h
00h
LByte
XXh
User data as sent
Stop 2-sheet
PLC
L20
0H110010
0Dh
00h
00h
00h
LByte
XXh
0 = no;
1 = yes;
PLC
L20
0H110010
0Dh
00h
00h
00h
LByte
XXh
User data as sent
External
Measuring start
PLC
L20
0H110010
0Eh 00h 00h 00h LByte XXh
1 = IN0 2 = IN0 + IN1
3 = IN0 + IN1 + IN2
PLC
L20
0H110010
0Eh
00h
00h
00h
LByte
XXh
User data as sent
Level 0-1-2
PLC
L20
0H110010
0Fh 00h 00h 00h LByte XXh
0 = 0 V active
1= 24 V active
PLC
L20
0H110010
0Fh
00h
00h
00h
LByte
XXh
User data as sent
External
adjustment
PLC
L20
0H110010
10h 00h 00h 00h 00h XXh
0 = no ext. adjustment
1 = ext. adjustment possible
PLC
L20
0H110010
10h
00h
00h
00h
00h
XXh
User data as sent
Sensor type
PLC
L20
0H110010
11h 00h 00h 00h LByte XXh
0 = LAAS10
1 = LAARS10
or
2 = LAAS40
3 =LAARS40
or
4 =LAAS200
5 =LAARS200
or
PLC
L20
0H110010
11h
00h
00h
00h
LByte
XXh
User data as sent
IN / OUT PLC
monitor
voltage
PLC
L20
0H110010
12h 00h 00h 00h LByte XXh
0 = no monitoring
1= monitoring
PLC
L20
0H110010
12h
00h
00h
00h
LByte
XXh
User data as sent
Password L20
PLC
L20
0H110010
13h
1
st
pos.
2
nd
pos.
3
rd
pos.
4
th
pos.
XXh
0 to 9 per digit
PLC
L20
0H110010
13h
1
st
pos.
2
nd
pos.
3
rd
pos.
4
th
pos.
XXh
User data as sent
Reserved
PLC
L20
0H110010
14h
00h
00h
00h
00h
XXh
0
PLC
L20
0H110010
14h
00h
00h
00h
00h
XXh
User data as sent
Unit version
PLC
L20
0H110010
15h
00h
00h
00h
LByte
XXh
0 = Standard
PLC
L20
0H110010
15h
00h
00h
00h
LByte
XXh
User data as sent
Unit series
PLC
L20
0H110010
16h
1 digit
1 digit
1 digit
1 digit
XXh
Plain text
„L _ _ _“
PLC
L20
0H110010
16h
1 digit
1 digit
1 digit
1 digit
XXh
User data as sent
Unit type
PLC
L20
0H110010
17h
1 digit
1 digit
1 digit
1 digit
XXh
Plain text
1 channel: „201P“ or „201R“
3 channel: „203P“ or „203R“
P = Profibus R = ProfiNet
PLC
L20
0H110010
17h
1 digit
1 digit
1 digit
1 digit
XXh
collision if data sent is not
identical with device
Software version
2)
PLC
L20
0H110010
18h
XXh
XXh
XXh
XXh
XXh
Content not relevant
PLC
L20
0H110010
18h HH HA 00h SV XXh
Send back from
HH = Hardware version
Mainboard
HA = Hardware version
Analog board
SV = Software version
2) System parameters will be saved with this command. Previously data is active, but without being saved on the device.