Double Sheet Control System R1000 series L20
with integrated fieldbus interface
Start-up
B0063191 / 1.3
86
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
This system parameters are only for EtherNet/IP
When DHCP is switched on, the IP-setting will be
done via DHCP. When DHCP is switched off, the IP-
address, SubNet and Gateway must be selected.
Fig. 67: Setting DHCP
The IP-address can be selected here.
Fig. 68: Setting IP-Address
The SubNet can be selected here.
Fig. 69: Setting SubNet
The Gateway can be selected here.
Fig. 70: Setting Gateway
System parameter 7:
Indicating of the the Bus baud rate.
Fig. 71: Indicating of the Bus baud rate
Setting the Bus baud rate depends on the Bus type:
Profibus: up to 12Mbps/s; selection at master
DeviceNet: 125/250/500/kBit
CanOpen: 10/20/50/125/250/500/800/1000 kbps
ProfiNet IO: ----
CC-Link: 125/625kbps 2,5/5/10Mbps
EtherNet/IP: – –
EtherCAT: – –
system parameter: 6
EthernetIP DHCP: no
system parameter: 6b
IP:
192.168. 0. 10
system parameter: 6c
Snet: 255.255.255. 0
system parameter: 6d
GWay: 0. 0. 0. 0
system parameter: 7
busbaudrate
500kb