Parameter channel commands (Read system parameters II)
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Command
Direction
of data
Management Program
index
Para
meter
index
User
data
byte 0
User
data
byte 1
User
data
byte 2
User
data
byte 3
Check-
sum
Range of values
Read syst
em par
amet
ers
Number of
measuring
channels
PLC
L20
0H110001
FFh
09h 00h 00h 00h 00h XXh
PLC
L20
0H110001
09h
00h
00h
00h
LByte
XXh
1 = one measuring channel
2 = two measuring channels
3 = three measuring channels
Default
moving average
PLC
L20
0H110001
0Ah 00h 00h 00h 00h XXh
PLC
L20
0H110001
0Ah
00h 00h 00h LByte XXh
0
=
250
ms;
1 = 100 ms;
2 = 50 ms;
3 = 25 ms;
4 = 15 ms;
2 = 8 ms;
Reserved
PLC
L20
0H110001
0Bh 00h 00h 00h 00h LByte
PLC
L20
0H110001
0Bh 00h 00h 00h 00h XXh
0
Measurement
mode of operation
PLC
L20
0H110001
0Ch 00h 00h 00h 00h XXh
PLC
L20
0H110001
0Ch
00h
00h
00h
LByte
XXh
0 = ext. single measurement
1 = demo operation
2 = ext. continuous meas.
3 = ext. special
Stop 2-sheet
PLC
L20
0H110001
0Dh 00h 00h 00h 00h XXh
PLC
L20
0H110001
0Dh
00h
00h
00h
LByte
XXh
0 = no;
1 = yes;
External
measuring start
PLC
L20
0H110001
0Eh 00h 00h 00h 00h XXh
PLC
L20
0H110001
0Eh 00h 00h 00h LByte XXh
1 = IN0 2 = IN0 + IN1
3 = IN0 + IN1 + IN2
level 0-1-2
PLC
L20
0H110001
0Fh 00h 00h 00h 00h XXh
PLC
L20
0H110001
0Fh 00h 00h 00h LByte XXh
0 = 0 V active
1= 24 V active
External
adjustment
PLC
L20
0H110001
10h 00h 00h 00h 00h XXh
PLC
L20
0H110001
10h 00h 00h 00h LByte XXh
0 = no ext. adjustment
1 = ext. adjustment
Sensor Type
PLC
L20
0H110001
11h 00h 00h 00h 00h XXh
PLC
L20
0H110001
11h 00h 00h 00h LByte XXh
0 = LAAS10
1 = LAARS10
or
2 = LAAS40
3 = LAARS40
or
4 = LAAS200
5 = LAARS200
or
IN / OUT PLC
monitor voltage
PLC
L20
0H110001
12h 00h 00h 00h 00h XXh
PLC
L20
0H110001
12h 00h 00h 00h LByte XXh
0 = no monitoring
1 = monitoring
Password L20
PLC
L20
0H110001
13h
00h 00h 00h 00h XXh
PLC
L20
0H110001
13h
1
st
pos.
2
nd
pos.
3
rd
pos.
4
th
pos.
XXh
0 to 9 per digit
Reserved
PLC
L20
0H110001
14h
00h 00h 00h 00h XXh
PLC
L20
0H110001
14h
00h 00h 00h 00h
XXh
0
Unit version
PLC
L20
0H110001
15h 00h 00h 00h 00h XXh
PLC
L20
0H110001
15h 00h 00h 00h LByte XXh
0
=
Standard
Unit series
PLC
L20
0H110001
16h 00h 00h 00h 00h XXh
PLC
L20
0H110001
16h
1
digit
1
digit
1
digit
1
digit
XXh Plain
text
„L _ _ _“
Unit type
PLC
L20
0H110001
17h 00h 00h 00h 00h XXh
PLC
L20
0H110001
17h
1
digit
1
digit
1
digit
1
digit
XXh Plain
text
1 channel: „201P“ or „201R“
3 channel: „203P“ or „203R“
P = Profibus R = ProfiNet
Software version
PLC
L20
0H110001
18h 00h 00h 00h 00h 00h
PLC
L20
0H110001
18h HH HA 00h SV XXh
HH = Hardware version
Mainboard
HA = Hardware version
Analog board
SV = Software version