Remote control commands
R&S
®
RTB2000
396
User Manual 1333.1611.02 ─ 11
D0..15
Active digital channels D0 to D15, available if MSO option
R&S
RTB-B1 is installed.
On individual digital channels, only vertical (time) cursor mea-
surements are possible.
D70 | D158
Active digital channels D0...D7 (pod
1) and D8...D15 (pod
2).
Only available, if MSO option R&S
RTB-B1 is installed. On pods,
only V-marker measurement is possible.
SPECtrum | MINHold | MAXHold | AVERage
FFT waveforms
Manual operation:
See
CURSor<m>:USSOURce
<UseSecondSource>
Enables the second cursor source. To select the second source, use
.
If enabled, the second cursor measures on the second source. Using a second source,
you can measure differences between two waveforms with cursors. Both sources must
be in the same domain (time domain or frequency domain).
Suffix:
<m>
.
1, the suffix is irrelevant.
Parameters:
<UseSecondSource> ON | OFF
*RST:
OFF
Manual operation:
See
CURSor<m>:SSOURce
<SecondSource>
Selects the second cursor source.
Suffix:
<m>
.
1, the suffix is irrelevant.
Parameters:
<SecondSource>
CH1 | CH2 | CH3 | CH4 | MA1 | MA2 | MA3 | MA4 | MA5 | RE1 |
RE2 | RE3 | RE4 | XY1 | XY2 | D70 | D158 | D0..15 | SPECtrum |
MINHold | MAXHold | AVERage
See
Manual operation:
See
CURSor<m>:TRACking[:STATe]
<State>
If set to ON, the V-Marker cursor measurement is enabled.
Measurements