Remote control commands
R&S
®
RTB2000
554
User Manual 1333.1611.02 ─ 11
Parameters:
<PatternPeriod>
Numeric value (Period = Pattern length * Bit time)
Range:
MIN 1 Sample * 20ns = 20ns to MAX 2048 Sam-
ples * 42s = 10416s (approx. 2.89h)
*RST:
2.000E-06
Default unit: s
Manual operation:
See
See
PGENerator:PATTern:FREQuency
<PatternFrequency>
Defines the frequency (period) value of the pattern generator function.
Parameters:
<PatternFrequency> Numeric value
Default unit: Hz
Manual operation:
See
15.13.2.3
Counter pattern
PGENerator:PATTern:COUNter:FREQuency
.....................................................................554
PGENerator:PATTern:COUNter:DIRection
........................................................................ 554
PGENerator:PATTern:COUNter:FREQuency
<Period>
Defines the frequency value of the pattern generator counter function. The user fre-
quency always refers to the switching of the pattern condition. This results in square
waveforms for individual pins.
Pin
Frequency
S0
f/2
S1
f/4
S2
f/8
S3
f/16
Parameters:
<Period>
Numeric value
Range:
2.380952425301E-02 to 2.50000007
*RST:
1.00000005
Default unit: Hz
Manual operation:
See
PGENerator:PATTern:COUNter:DIRection
<CountDirection>
Sets the pattern generator counter direction.
Signal generation (option R&S
RTB-B6)