Remote control commands
R&S
®
RTB2000
501
User Manual 1333.1611.02 ─ 11
Manual operation:
See
BUS<b>:CAN:SAMPlepoint
<SamplePoint>
Sets the position of the sample point within the bit in percent of the nominal bit time.
See also:
Suffix:
<b>
.
1 | 2
Parameters:
<SamplePoint>
Range:
10 to 90
Increment: 1
*RST:
50
Default unit: %
Manual operation:
See
BUS<b>:CAN:BITRate
<BitRate>
Sets the number of transmitted bits per second.
Suffix:
<b>
.
1 | 2
Parameters:
<BitRate>
Range:
100 to 2E06
Increment: Depends on the bit rate value
*RST:
50E03
Default unit: Bit/s
Manual operation:
See
15.11.5.2
CAN - trigger
To configure the protocol trigger, make sure to set first:
●